Description
Incubator Temperature Controller Digital for Hatchery and Refrigerators 110V to 220V
Item Type: Incubator Temperature Controller_x000D_
Material: ABS_x000D_
Power Supply Voltage: AC110-230V_x000D_
Power Supply Frequency: 50/60Hz_x000D_
Temperature Measurement Range: -40-110_x000D_
Temperature Measurement Accuracy: 0.3_x000D_
Humidity Measurement Range: 0%-100%RH_x000D_
Humidity Measurement Accuracy: 3%_x000D_
Output Control: Relay Output_x000D_
Output Power: Mximum 10A_x000D_
Installation Hole Size: Approx. 28 x 70mm/1.1 x 2.8in_x000D_
Setup essential_x000D_
Start value Stop value (The program automatically determines that the working mode is cooling/dehumidifying mode)_x000D_
Heating/cooling mode setting_x000D_
Setting method:_x000D_
Setting (start temperature): long press the 1 button, the start temperature flashes, and set the start temperature value through the 11 key_x000D_
Setting (stop temperature): long press the 1 button to stop the temperature flashing, and set the stop temperature value through the 11 button._x000D_
Heating use case:_x000D_
Control the water heater, stop heating to 70C, start heating again when the temperature drops to 45C, and cycle_x000D_
Step 1: Heating working mode, starting temperature stop temperature_x000D_
Step 2: Long press the 1 button, the start temperature flashes, and set the start temperature to 30 by pressing the 11 button_x000D_
Step 3: Long press the 1 button to stop the temperature flashing, and set the stop temperature to 25 through the 1 button, and the setting is complete! If there is no operation for 10 seconds, it will automatically return to the normal display state. You can also press 22 to exit immediately._x000D_
Humidification/dehumidification mode setting_x000D_
Setting method:_x000D_
Setting (starting humidity): long press the 2 key, the start humidity value flashes, and set the start humidity value through the 22 key._x000D_
Setting (stop humidity): Long press the 2 key to stop the flashing of the humidity value, and set the stop humidity value through the 22 key._x000D_
Humidification example:_x000D_
To humidify the supermarket, control the humidifier to 50% RH to start humidifying, and to stop humidifying when humidified to 80% RH._x000D_
Setting steps:_x000D_
Step 1: Long press the 2 key to start the humidity value flashing, and use the 22 key to set the start humidity value to 50%RH_x000D_
Step 2: Long press the 2 key to stop the humidity value flashing, and set the stop humidity value to 80%RH through the 22 key, and the setting is complete! Press the key for 10 seconds without operation, it will automatically return to the normal display state, or you can press the 11 key to exit immediately._x000D_
Dehumidification example:_x000D_
Workshop control exhaust dehumidification system, humidity 75%RH starts dehumidification, humidity 45%RH stops dehumidification_x000D_
Setting steps:_x000D_
Step 1: Long press the 2 key to start the humidity value flashing, and use the 22 key to set the starting humidity value to 75%RH_x000D_
Step 2: Long press the 2 key to stop the humidity value flashing, and set the stop humidity value to 45%RH by pressing the 22 key, and the setting is complete! Press the key for 10 seconds with
-
Fruugo ID:
313593112-699776680
-
EAN:
3586285255894
Product Safety Information
Please see the product safety information specific to this product outlined below
The following information is provided by the independent third-party retailer selling this product.
Product Safety Labels
Safety Warnings:
Do not use in high or low temperature environments
Delivery & Returns
Dispatched within 24 hours
Shipping from China.
We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy